Products

contact us ¹Ù·Î°¡±â
HT-070 SERIES
HOME / Products / Truck refrigeration unit / Direct drive unit / 070 SERIES

HT-070 SERIES

HT-070 II ¡¤ HT-070ESC II

For Frozen 13m3 ~ Fresh 21m3 Truck

HT-070 II

¡¤ HFC R-134a or R-404a Chlorine zero
¡¤ Front mounted condenser operated by vehicle
  engine and compressor
¡¤ Durable ABS plastic cover with aerodynamic design

HT-070ESC II

¡¤ HFC R-134a or R-404a Chlorine zero
¡¤ Front mounted condenser operated by
  vehicle engine or electric standby motor
¡¤ Durable ABS plastic cover with
   aerodynamic design

EVAPORATOR
FOR HT-070 II, HT-070ESC II

¡¤ Slim ceiling Evaporator
¡¤ Maximum load space and high airflow volume
¡¤ 2 Evaporator Fans

VALEO TM-15HS

Lower vibrations and higher strength
for Heavy-duty jobs

¢ºEngine compressor ¡¤ Electric Standby
compressor

Displacement - 147cc
No. of Cylinders - 6 (3 double-headed pistons)
Revolution range - 700~6000 rpm
Oil - ZXL 100PG PAG OIL (150cc)

Temperature controller

¢ºIn-cab control system
¡¤ Automatic start/stop engine operation
  by setting temperature
¡¤ Check engine operation hour
¡¤ Check engine operation hour
¢ºDefrost
¡¤ Automatic hot gas defrost initiated and terminated
  by cab controller

 

Refrigeration Capacity

Cooling Capacity Temperature Road operation
HT-070 II
Electric operation
HT-070 ESC II
30¡ÆC(86¡ÆF) Ambient under ATP Standard R-404A ¡É kcal/h watt kcal/h watt
0 2,263 2,632 1,768 2,056
-10 1,733 2,016 1,300 1,512
-20 1,241 1,443 908 1,056
Engine
Compressor
Model TM-15
No. of Cylinder 6
Displacement(§¨) 147
Refrigerant R-404a 1.3kg / R-134a 1.3kg
Airflow Volume @ 0 Pa static Pressure 794m©ø/h
DC Voltage Option DC 12V / DC 24V
Electric Standby Power - 220/380/415V,1P/3P,50/60Hz
Output - 2.2kW(3HP)
Defrost Automatic hot gas defrost initiated & terminated by cab controller
Size (LxWxH) / mm & Weight / kg Condenser 1090 x 470 x 258 (25) 1230 x 570 x 330(115)
Evaporator 840 x 629 x 163 (20) 840 x 629 x 163 (20)
Cab control 105 x 75 x 48

Optional Features

¢º Heating system
: When the ambient is lower than the temperature in the truck body then, heating system[hot gas, hot water &   electric coil] is used to protect the products from frozen.